MotoCrane Revolt status LED colors and troubleshooting

Revolt's status LED shows standby, input voltage bands, over-voltage, and Auto-On state. Most Ronin 2 power problems come down to firmware, polarity or a source above 27.5V.

Applies to: MotoCrane Revolt

Download the field card (PDF)

What do the MotoCrane Revolt LED colors mean?

  1. 1Power up

    Connect power. Revolt goes to standby (strobing white). Hold the ON/OFF button on Revolt or the Ronin 2 until the Ronin 2 starts.

  2. 2Regulated sources

    With a block battery, AC-3 or DC-3 the output voltage is fixed, so the LED will not fall as the battery drains. Watch voltage at the source. The Ronin app will show 101 percent.

  3. 3Check Ronin 2 firmware

    Firmware 1.3.0.60 (or a reading of 0.0.0.0) is not compatible. 1.7.1.00 is recommended. 1.5.0.80, 1.2.0.50 and 1.1.0.30 also work.

  4. 4Check polarity

    AC-3, DC-3 and BBR use Arri 3-pin XLR polarity: pin 1 negative, pin 2 positive. Confirm third-party gear is not Panavision polarity. The BBR has no reverse polarity protection on its input.

  5. 5Ronin 2 will not start on a 28V block

    Some Ronin 2 units will not start at 27.5V or more. Use the BBR to drop a 28V source to 26VDC.

  6. 6No power from AC-3 or DC-3

    The breaker likely tripped. Check the load is not shorted and is within ratings, then cycle the power switch.

Revolt status LED (Revolt Operation Manual v1.1)
LEDMeaning
OffNo power, or reverse polarity
Strobing whiteStandby, ready to power on
Solid greenOn, 23.0 to 29.0V
Solid yellowOn, 22.0 to 23.0V
Solid orangeOn, 21.5 to 22.0V
Solid redOn, 12 to 21.5V
Blinking redOver-voltage, above 29.0V
Blue, blue, greenAuto-On enabled
Blue, blue, redAuto-On disabled
  • Do not cover the AC-3 fan. Secure the AC-3 and DC-3 so they cannot slide in the vehicle.
  • Medium to heavy loads, or long cable runs, need MotoCrane High Capacity 3-pin XLR cables to avoid voltage drop and heat.

Sources from MotoCrane