Moving Shot

MotoCrane RADICAL Error 029: Lift Motor Command Timeout

The lift driver is not getting commands from the Controller. The Controller is the most likely cause, and a power cycle often clears it. If it does not, the Controller may be damaged.

Error: red icon, repeated beeps until acknowledged. Fix before you continue.

What to do

  1. Power cycle the system.
  2. Check every cable connection.
  3. With the system disarmed, open the Diagnostics page and move the lift joystick to see if motor commands register.

First, always: check every cable and the COM and Power LEDs on each module. Axis: lift. Applies to MotoCrane RADICAL.

Code 029 on ULTRA is different: ULTRA Error 029: Lift Motor Command Timeout.

Print the RADICAL code card (PDF)

Related lift codes