MotoCrane error code

MotoCrane RADICAL Error 233: Lift Control Mode Disabled From Error

Each control mode needs certain hardware working. STANDARD mode on the lift axis needs steady data from the lift encoder. If that data drops out, the system leaves STANDARD mode and shows this code. It also appears if too much lift travel trips the mechanical limit switch.

Error: red icon, repeated beeps until acknowledged. Fix before you continue.

What to do

  1. Check STATUS and LOG to find the cause.
  2. Power cycle and try to re-enable the mode.

First, always: check every cable and the COM and Power LEDs on each module. Axis: lift. Applies to MotoCrane RADICAL.

Print the RADICAL code card (PDF)

Related lift codes

Sources from MotoCrane

RADICAL code 233: quick answers

What does MotoCrane RADICAL error 233 mean?
Each control mode needs certain hardware working. STANDARD mode on the lift axis needs steady data from the lift encoder. If that data drops out, the system leaves STANDARD mode and shows this code. It also appears if too much lift travel trips the mechanical limit switch.
How do I clear RADICAL code 233?
Check STATUS and LOG to find the cause. Power cycle and try to re-enable the mode.