MotoCrane RADICAL won't turn on: power path checklist
Isolate a no-power RADICAL one link at a time: power source, PSU, controller cable, main power output cable, Cortex to Fulcrum cable, then the Cortex. Assumes the PSU system power switch is on and the controller does not boot.
Applies to: MotoCrane RADICAL
Download the field card (PDF)What do I check when a MotoCrane RADICAL won't power on?
1Read the PSU voltmeter
If the SYS POWER voltmeter is off, check the power source. It must be above 42V. If the source is good and the meter is still dark, the PSU has likely failed.
2Check the COM PWR LED
If the voltmeter reads but the PSU COM PWR LED is not green, turn the system off, unplug the controller cable from the COM port, and power up again.
3Isolate the controller cable
If the voltmeter now stays on, the controller or its cable is damaged. Try a spare controller cable first.
4Isolate the main power output cable
If the voltmeter still drops, power off, disconnect the main power output cable from the PSU and power up. A meter that now stays on points to the main power output cable, or to the Base or Cortex.
5Isolate the Cortex to Fulcrum cable
Power off, remove the short Cortex to Fulcrum cable, and power on. If things recover, that cable or the Fulcrum is damaged.
6Reverse polarity circuit
If the PSU survives but shows signs of a reverse polarity event, the guide describes a bypass procedure. The system can run without the protection circuit, but it needs replacing. This is a technician procedure: contact MotoCrane Support.
7Last step
If every cable checks out, the Cortex is likely damaged and needs replacing.
- A red Fault LED near the PSU SYSTEM POWER INPUT means a problem with the power source, for example reverse polarity.
- Power LEDs can stay dimly lit for a short time after power is switched off. That is normal.
Sources from MotoCrane
More guides
- MotoCrane RADICAL swing not working: field checklist
- MotoCrane RADICAL lift not working: field checklist
- Reading MotoCrane RADICAL LEDs, warnings and the System Log
- How to power a MotoCrane RADICAL or ULTRA with 48V
- MotoCrane RADICAL payload and counterweight balance
- MotoCrane RADICAL maintenance and weather care